Fire protection for vertiports covers how a vertiport prevents, detects and fights fires, and how people are rescued if a fire breaks out. Traditional heliport rules focus on fuel fires, which are usually tackled with foam. Electric air taxis add a different hazard: lithium-ion battery packs that can go into thermal runaway. This is a self-heating chain reaction that can release toxic, flammable gases, and the battery can reignite hours after the fire seems to be out. These fires are hard to smother, so firefighters usually rely on long periods of cooling with water and on keeping a damaged aircraft away from other aircraft and people.

Typical measures include fire-resistant surfaces, firefighting equipment and trained staff close to the TLOF and FATO, emergency cut-offs for chargers, clear access for fire engines, and drainage that stops contaminated water from spreading. Rooftop vertiports also raise questions about the building's structure and how people get out in an emergency.

The rules are still being developed. The FAA's Engineering Brief 105A points designers to existing fire standards, notably NFPA 418 (heliports and vertiports) and NFPA 855 (energy storage systems), while research on battery fires continues. EASA and other regulators set their own requirements, and the details differ. Sri Lanka has no vertiport standard yet, so any permanent site would need fire arrangements agreed with CAASL and the local fire services.

වර්ටිපෝට් සඳහා ගිනි ආරක්ෂාව

විදුලි ගුවන් යානාවල ලිතියම්-අයන බැටරි ගිනි ඇතුළුව ගිනි වැළැක්වීමට, හඳුනාගැනීමට, නිවීමට සහ මිනිසුන් ආරක්ෂිතව බේරා ගැනීමට වර්ටිපෝට් එකක් ගන්නා පියවර.

වර්ටිපෝට් සඳහා ගිනි ආරක්ෂාව යනු වර්ටිපෝට් එකක ගිනි වළක්වන, හඳුනාගන්නා සහ නිවන ආකාරයත්, ගින්නක් ඇති වුවහොත් මිනිසුන් බේරා ගන්නා ආකාරයත් ය. සාම්ප්‍රදායික හෙලිපෝට් නීති ප්‍රධාන වශයෙන් ඉන්ධන ගිනි ගැන සලකා බලන අතර, ඒවා සාමාන්‍යයෙන් පෙණ (foam) යොදා නිවනු ලැබේ. විදුලි ගුවන් ටැක්සි නිසා වෙනස් අවදානමක් එකතු වේ. ඒ, තාප පාලනයෙන් ගිලිහීම (thermal runaway) ඇති විය හැකි ලිතියම්-අයන බැටරි ය. එය තමන්ම රත් වන දාම ප්‍රතික්‍රියාවකි. එයින් විෂ සහිත, දැවෙන වායු පිට විය හැකි අතර, ගින්න නිවී ඇති සේ පෙනී පැය ගණනකට පසුවත් බැටරිය නැවත ගිනි ගත හැකි ය. මෙවැනි ගිනි යටපත් කිරීම අපහසු නිසා ගිනි නිවන්නන් සාමාන්‍යයෙන් දිගු වේලාවක් ජලයෙන් සිසිල් කිරීමත්, හානි වූ යානය වෙනත් යානාවලින් සහ මිනිසුන්ගෙන් ඈත් කර තැබීමත් කරති.

සුලබ පියවර අතර ගින්නට ඔරොත්තු දෙන මතුපිට, ගොඩබෑමේ ප්‍රදේශය (TLOF) සහ FATO ආසන්නයේ ගිනි නිවීමේ උපකරණ සහ පුහුණු කාර්ය මණ්ඩලය, චාජර් සඳහා හදිසි විදුලි විසන්ධි කිරීම, ගිනි නිවීමේ රථවලට පහසු ප්‍රවේශය සහ දූෂිත ජලය පැතිරීම වළක්වන ජලාපවහනය ඇතුළත් වේ. ගොඩනැගිලි වහල මත වර්ටිපෝට් සම්බන්ධයෙන් ගොඩනැගිල්ලේ ව්‍යුහය සහ හදිසි අවස්ථාවක මිනිසුන් පිටතට යන ආකාරය ගැනත් ප්‍රශ්න මතු වේ.

නීති තවමත් සකස් වෙමින් පවතී. FAA ආයතනයේ ඉංජිනේරු නිවේදනය 105A (Engineering Brief 105A) මගින් නිර්මාණකරුවන් NFPA 418 (හෙලිපෝට් සහ වර්ටිපෝට්) සහ NFPA 855 (බලශක්ති ගබඩා පද්ධති) වැනි දැනට පවතින ගිනි ප්‍රමිතීන් වෙත යොමු කරන අතර, බැටරි ගිනි පිළිබඳ පර්යේෂණ දිගටම සිදු වේ. EASA සහ අනෙකුත් නියාමකයින් තමන්ගේම අවශ්‍යතා පනවන අතර, විස්තර එකිනෙකට වෙනස් ය. ශ්‍රී ලංකාවට තවමත් වර්ටිපෝට් ප්‍රමිතියක් නැති නිසා, ඕනෑම ස්ථිර ස්ථානයක ගිනි ආරක්ෂණ විධිවිධාන ශ්‍රී ලංකා සිවිල් ගුවන් සේවා අධිකාරිය (CAASL) සහ ප්‍රාදේශීය ගිනි නිවීමේ සේවා සමඟ එකඟ වී සකස් කළ යුතු වේ.

வெர்டிபோர்ட்களுக்கான தீ பாதுகாப்பு

மின்சார விமானங்களின் லித்தியம்-அயன் பேட்டரி தீ உட்பட தீயைத் தடுக்கவும், கண்டறியவும், அணைக்கவும், மக்களைப் பாதுகாப்பாக மீட்கவும் வெர்டிபோர்ட் எடுக்கும் நடவடிக்கைகள்.

வெர்டிபோர்ட்களுக்கான தீ பாதுகாப்பு என்பது ஒரு வெர்டிபோர்ட் தீயை எவ்வாறு தடுக்கிறது, கண்டறிகிறது, அணைக்கிறது என்பதையும், தீ ஏற்பட்டால் மக்கள் எவ்வாறு மீட்கப்படுகிறார்கள் என்பதையும் குறிக்கிறது. பாரம்பரிய ஹெலிபோர்ட் விதிகள் முக்கியமாக எரிபொருள் தீயைக் கவனத்தில் கொள்கின்றன. அவை பொதுவாக நுரை (foam) மூலம் அணைக்கப்படுகின்றன. மின்சார வான் டாக்ஸிகள் வேறொரு ஆபத்தைக் கொண்டுவருகின்றன. அதாவது, கட்டுப்பாடற்ற வெப்ப அதிகரிப்புக்கு (thermal runaway) உள்ளாகக்கூடிய லித்தியம்-அயன் பேட்டரிகள். இது தானாகவே சூடாகும் ஒரு சங்கிலித் தொடர் எதிர்வினை. இதனால் நச்சுத்தன்மையுள்ள, எளிதில் தீப்பற்றும் வாயுக்கள் வெளியேறலாம். தீ அணைந்துவிட்டதாகத் தோன்றிய பல மணிநேரங்களுக்குப் பிறகும் பேட்டரி மீண்டும் தீப்பற்றக்கூடும். இத்தகைய தீயை அடக்குவது கடினம். எனவே தீயணைப்பாளர்கள் பொதுவாக நீண்ட நேரம் தண்ணீரால் குளிர்விப்பதையும், சேதமடைந்த விமானத்தை மற்ற விமானங்களிலிருந்தும் மக்களிடமிருந்தும் தனிமைப்படுத்துவதையும் நம்பியிருக்கிறார்கள்.

தீயைத் தாங்கும் மேற்பரப்புகள், தரையிறங்கும் பகுதி (TLOF) மற்றும் FATO அருகில் தீயணைப்பு உபகரணங்களும் பயிற்சி பெற்ற ஊழியர்களும், சார்ஜர்களுக்கான அவசர மின் துண்டிப்பு, தீயணைப்பு வாகனங்கள் எளிதில் வந்துசேரும் வழி, மாசடைந்த நீர் பரவுவதைத் தடுக்கும் வடிகால் அமைப்பு ஆகியவை வழக்கமான நடவடிக்கைகளில் அடங்கும். கட்டடங்களின் கூரை மீது அமையும் வெர்டிபோர்ட்கள் தொடர்பில், கட்டடத்தின் கட்டமைப்பு மற்றும் அவசரநிலையில் மக்கள் வெளியேறும் முறை பற்றிய கேள்விகளும் எழுகின்றன.

விதிகள் இன்னும் உருவாக்கப்பட்டு வருகின்றன. FAA வின் பொறியியல் சுருக்கம் 105A (Engineering Brief 105A), NFPA 418 (ஹெலிபோர்ட்கள் மற்றும் வெர்டிபோர்ட்கள்), NFPA 855 (ஆற்றல் சேமிப்பு அமைப்புகள்) போன்ற தற்போதுள்ள தீ தரநிலைகளை வடிவமைப்பாளர்களுக்குச் சுட்டிக்காட்டுகிறது. அதேவேளை பேட்டரி தீ பற்றிய ஆய்வுகள் தொடர்கின்றன. EASA மற்றும் பிற ஒழுங்குமுறை அமைப்புகள் தமக்கென தனித் தேவைகளை விதிக்கின்றன. அவற்றின் விவரங்கள் வேறுபடுகின்றன. இலங்கையில் இன்னும் வெர்டிபோர்ட் தரநிலை இல்லை. எனவே எந்தவொரு நிரந்தர தளத்துக்கும் தேவையான தீ பாதுகாப்பு ஏற்பாடுகள் இலங்கை சிவில் விமான சேவைகள் அதிகாரசபை (CAASL) மற்றும் உள்ளூர் தீயணைப்புச் சேவைகளுடன் இணக்கம் கண்டு செய்யப்பட வேண்டும்.

Related: Thermal runaway, Vertiport, TLOF (touchdown and lift-off area), FATO (final approach and take-off area), Vertiport charging infrastructure