At a glance
- Screening grade
- C
- District
- Ampara
- Planner score
- 34/100
- Airspace
- none
- Residents within 2 km
- 17,281
- Departure headings
- 30° / 165°
- Coordinates
- 7.2748, 81.8658
Summary
Oluvil Port is a cargo-category candidate in Ampara District, Eastern Province. The headline constraint is the ground itself. The 200 m cell at the plotted point is classed as water, with a surface-water occurrence of 81%, although the dataset flags it as on land. On current information we cannot confirm a dry pad location. Airspace and terrain look favourable on the desk data. The demand case is weak. Our judgement is Grade C: workable only if a suitable land-side parcel is found and a real cargo need is shown.
Location and catchment
The site is at 7.27479° N, 81.86583° E. About 952 residents live within 500 m, 17,281 within 2 km and 133,333 within 10 km. These are night-time resident counts, not port workers or visitors. Night-light radiance is 1.6, which suggests modest activity at night.
The site is 226.1 km from Port City Colombo, so there is no link to the current sandbox. The nearest base hospital, Ashraff Memorial Hospital (Base Hospital Kalmunai South), is 14.8 km away. OSM lists Oluvil Hospital at 1,890 m and Palamunai Hospital at 2,022 m. Ampara (Gal Oya) airport is 26.9 km away and Arugam Bay is 47.7 km away. Both are beyond the roughly 24 km practical range of the EH216-S on test.
Airspace
The airspace grid shows no class, and the site is inside no listed controlled, restricted or prohibited area. The nearest boundary is the Amparai CTR at 8.42 km, and the Batticaloa CTR is 33.62 km away. In our judgement airspace is not a primary constraint. CAASL would still regulate any operation, and coordination near the Amparai CTR should be expected.
Approach paths and terrain
The terrain is flat. Site elevation is 0 m, mean slope within 500 m is 0.2° and the maximum is 1.0°. The 8:1 terrain check gives 12 m minimum clearance at 100 m on all 16 headings, so no terrain penetration was found on the 200 m model. This check ignores buildings, trees, towers and power lines. At a port it also misses cranes, masts and vessels, which may be the controlling obstacles.
Headings below are the directions the aircraft flies when departing; each approach is the reciprocal.
- Primary departure heading: 030°. This faces into the NE-monsoon prevailing wind from 031°, the steadiest season (steadiness 0.81).
- Secondary departure heading: 165°. This faces into the SW-monsoon wind from 166° and is 135° from the primary, which meets the EB 105A minimum separation.
Space and layout
Within 500 m the land cover is 33% water, 31% grassland, 22% built-up and 11% bare or sparse. Built-up cover in the site cell is 2%. For the largest EB 105A Reference Aircraft, the Safety Area alone is about 38 m × 38 m (≈1,450 m²), before taxiways, charging, cargo handling and the passenger area. A ministry figure gives under 900 m² per pad for an EH216-S class vertiport. The grassland and bare land nearby suggest space may exist. This is our inference: the data does not identify a parcel. A ground-level pad must avoid loose debris, needs drainage no steeper than 2:1, and needs a safety barrier. The downwash caution area may extend beyond the Safety Area into working port space.
Wind and weather
ERA5 data for 2015–2024 is taken from a point 14.8 km away and is coarse. Mean wind is 1.8 m/s: 1.7 m/s in the SW monsoon and 2.9 m/s in the NE monsoon. Mean daily maximum wind ranges from 4.2 to 5.1 m/s. Gusts above 15 m/s occur on 0.5% of days or fewer in every season, and none above 20 m/s.
Rain is the main weather factor. Monthly rainfall averages 335 mm in the NE monsoon and 230 mm in Oct–Nov. More than 20 mm falls on 6.3% and 9.8% of days in those seasons, against 35 mm a month in the SW monsoon. Under VFR-only operation, wet-season availability is likely to fall. Wind direction is unsettled in Oct–Nov (steadiness 0.26) and moderately steady in the SW monsoon (0.44). Sea-breeze effects are not resolved by ERA5.
Environment and neighbours
The site is not in a WDPA protected area, and no nearby protected area is listed. OSM shows no schools or places of worship within 500 m and no heritage features within 1 km. OSM completeness varies, so this is not proof of absence. With 952 residents within 500 m, noise and outwash exposure need assessment. The large share of water nearby means coastal and water-body impacts should be reviewed.
What would need to be checked
- The exact pad location, a dry and flood-safe parcel, and why the data shows a water cell flagged as on land.
- Port operator consent, land status, and compatibility with port security and operations.
- An obstacle survey of cranes, masts, towers, lines and vessels along the 030° and 165° paths.
- CAASL and SLAF coordination given the Amparai CTR 8.42 km away.
- Local wind measurement covering at least the ten-year basis recommended in EB 105A, including sea-breeze effects.
- Evidence of cargo demand within the range of available aircraft.
- Fire protection to NFPA 418 and NFPA 855 for charging and batteries.
This is a desk-based planning screen using open data, not a survey, design or approval.
Scorecard
| Criterion | Rating | Evidence |
|---|---|---|
| Demand and catchment | 2/5 | There are 17,281 residents within 2 km and 133,333 within 10 km. Night-light radiance is low at 1.6. The site is 226.1 km from Port City, and there is no tourism node within 47.7 km. |
| Airspace | 4/5 | The grid shows no controlled, restricted or prohibited airspace at the site. The nearest boundary is the Amparai CTR, 8.42 km away, and the Batticaloa CTR is 33.62 km away. |
| Terrain and approach paths | 4/5 | Elevation is 0 m and the maximum slope within 500 m is 1.0°. All 16 headings show 12 m minimum clearance at 100 m, with no terrain penetration found on the 200 m model. The check ignores buildings, cranes, masts and vessels. |
| Footprint and land | 2/5 | The site cell is classed as water, with 81% water occurrence, although the data flags it as on land. Within 500 m the land cover is 33% water, 31% grassland, 22% built-up and 11% bare or sparse, so a land-side pad may exist but has not been identified. |
| Wind and weather | 3/5 | Mean wind is 1.8 m/s. Gusts above 15 m/s occur on 0.5% of days or fewer in every season. NE monsoon rainfall averages 335 mm a month, and 6.3% of NE-monsoon days and 9.8% of Oct–Nov days have more than 20 mm of rain. The ERA5 values come from a point 14.8 km away. |
| Environment and protected areas | 3/5 | The site is not in a WDPA protected area, and no protected area is listed nearby. A third of the 500 m neighbourhood is water, so coastal and water-body impacts need checking. |
| Noise and neighbours | 3/5 | 952 residents live within 500 m. OSM shows no schools, places of worship or heritage features within 500 m–1 km, but OSM completeness varies. |
| Connectivity and emergency value | 2/5 | The nearest base hospital is 14.8 km away, and two local hospitals are about 1.9–2.0 km away. Ampara (Gal Oya) airport is 26.9 km away, beyond the 24 km practical range of the EH216-S on test. |
Key risks
- The plotted site cell is mapped as water (81% occurrence), so a dry, stable pad location has not been established.
- Port obstacles (cranes, masts, moored vessels, lighting towers) are not captured by the terrain-only 8:1 check.
- Demand is weak: low night lights (1.6) and no strong passenger or tourism node within range.
- Range: Ampara airport (26.9 km) and Arugam Bay (47.7 km) are beyond the 24 km practical range of the EH216-S on test.
- Heavy NE-monsoon and Oct–Nov rainfall (335 and 230 mm a month) is likely to cause seasonal disruption.
- Downwash and outwash near port workers, cargo handling and 952 residents within 500 m.
Open questions
- Is there a dry, firm, flood-safe land parcel within the port area large enough for a ~38 m × 38 m Safety Area plus support facilities?
- Why does the data flag the site as on land when the cell is mapped as water with 81% water occurrence? Confirm the exact pad location.
- Port operator consent, land status and compatibility with port operations and security.
- An obstacle survey of cranes, masts, towers, power lines and vessel air draughts along the 030° and 165° paths.
- CAASL and SLAF views on operations 8.42 km from the Amparai CTR.
- Coastal environmental, erosion and flood-exposure review of the chosen pad.
- Local wind measurement, including sea-breeze effects, because the ERA5 data is from 14.8 km away at 25–30 km resolution.
- Is there an actual cargo demand: what goods, which destinations, and within what range?
Desk-based planning screen using open data (routes.evtol.lk planner layers, OpenStreetMap, ERA5 2015–2024) and the FAA Engineering Brief 105A as a design reference. It is not a survey, design or approval; Sri Lanka has not published a vertiport standard. Drafted with an AI model constrained to the data, then independently fact-checked.