At a glance
- Screening grade
- D
- District
- Gampaha
- Planner score
- 0/100
- Airspace
- Prohibited
- Residents within 2 km
- 39,158
- Departure headings
- 225° / 45°
- Coordinates
- 6.9634, 79.9579
Summary
This candidate site at Sapugaskanda, in Gampaha District, sits inside prohibited area VCP22, Sapugaskanda Oil Refinery. VCP22 runs from ground level to FL300. That is the headline constraint. The site is also inside restricted area VCR23 (Colombo City Restricted Area) and the Colombo joint control zone, which covers Katunayake and Ratmalana. In Sri Lanka, prohibited areas need a specific dispensation, and restricted areas need Air Force approval.
On the desk data, the terrain is gentle and the winds are light. The airspace status and the industrial setting outweigh these points. Our judgement is grade D: blocked on current information. The site was listed as a cargo candidate. Any cargo case would depend on a dispensation and on the refinery's own safety rules.
Location and catchment
The site is at 6.96336 N, 79.95789 E, at about 30 m elevation, in Western Province. Resident population is:
- 1,241 people within 500 m
- 39,158 people within 2 km
- 1,429,744 people within 10 km
These are night-time residents, not workers or visitors. Night lights radiance is 78.4, which indicates a well-lit, developed area.
Distances to other places:
- Port City Colombo: 12.8 km
- Colombo North Teaching Hospital, Ragama: 8.2 km
- Colombo Ratmalana airport: 17.6 km
- Negombo: 30.6 km
The 12.8 km hop to Port City is within the roughly 24 km practical range of the EH216-S now on test. Negombo, at 30.6 km, is beyond that range.
Airspace
The site is inside three airspace volumes:
| ID | Name | Type | Limits |
|---|---|---|---|
| VCP22 | Sapugaskanda Oil Refinery | Prohibited | GND–FL300 |
| VCR23 | Colombo City Restricted Area | Restricted | GND–FL245 |
| CTR-COLOMBO | Colombo joint CTR | Control zone | GND–4000 ft |
Nearby prohibited areas include VCP34 (Defence Headquarters Complex, Akuregoda) at 6.51 km and VCP30 (Orugodawatta petroleum storage) at 7.41 km. Routes to the south-west would need to be planned around them.
Port City also operates inside a prohibited area, VCP29, under a dispensation. That precedent shows a dispensation is possible in principle. It does not show that one would be granted over an operating refinery. That is a matter for the CAA of Sri Lanka (CAASL) and the Air Force.
Approach paths and terrain
Convention: headings are the directions the aircraft flies when departing. Each approach is the reciprocal.
- Primary departure: 225°. This is into the SW-monsoon wind, which blows from 223° with steadiness 0.94.
- Secondary departure: 45°. This is the reciprocal of the primary. It also lies near the NE-monsoon wind, which is mostly from the NNE.
The terrain check sampled 16 headings on the 200 m elevation model. All 16 showed positive clearance against the 8:1 approach surface: 12 m to 22 m, at 100 m from the site. So no terrain penetration was found on the 200 m model.
This check ignores buildings, stacks, tanks, towers and power lines. At a refinery, those are likely to be the controlling obstacles. The site slope is 2.0°, the mean slope within 500 m is 2.4° and the maximum is 10.0°.
Space and layout
The 200 m site cell is 48% built-up. The surrounding 500 m is 72% built-up and 28% tree cover.
Sizing references:
- FAA EB 105A: the safety area for the largest reference aircraft is about 38 m × 38 m (about 1,450 m²), before taxiways, parking, charging and passenger areas.
- Ministry figure: under 900 m² per pad for an EH216-S class vertiport.
The data does not show whether open, level, debris-free ground of this size exists. It also does not show whether a downwash caution area could be kept clear of people. FAA research found strong outwash 38.5 m from the pad centre for some designs.
Battery storage and charging would fall under NFPA 855, and fire protection under NFPA 418. How these would fit with petroleum-processing hazard zones is unknown.
Wind and weather
These ERA5 statistics come from a grid point 3.4 km away, at Kelani River, Peliyagoda. ERA5 grid spacing is about 25–30 km, so it smooths out local effects such as sea breezes. Mean wind is 1.6 m/s.
| Season | Wind from | Steadiness | Mean daily max wind | Days with gusts over 15 m/s | Days with over 20 mm rain | Average rain per month |
|---|---|---|---|---|---|---|
| May–Sep (SW monsoon) | 223° | 0.94 | 4.7 m/s | 3.0% | 8.5% | 200 mm |
| Dec–Feb (NE monsoon) | 11° | 0.66 | 3.5 m/s | 0% | 3.8% | 120 mm |
| Mar–Apr | 211° | 0.65 | 3.1 m/s | 0% | 4.1% | 235 mm |
| Oct–Nov | 245° | 0.33 | 3.5 m/s | 1.0% | 16.9% | 400 mm |
In our judgement, wind is not a limiting factor. Heavy rain in Oct–Nov would reduce the number of days when visual (VFR) flying is possible.
Environment and neighbours
The site is not in a protected area. The nearest is Bellanwila - Attidiya Sanctuary, 8.38 km away. Surface water occurrence is 0%.
OpenStreetMap shows no schools or places of worship within 500 m, no heritage features within 1 km and no hospitals within 3 km. OSM may be incomplete, so this does not prove they are absent. With 1,241 residents within 500 m, noise and overflight acceptance would need to be tested.
What would need to be checked
- Whether CAASL and the Air Force would consider a dispensation inside VCP22 and VCR23.
- The refinery operator's cargo need and its hazardous-area rules.
- A survey of obstacles, including stacks and structures, along headings 225° and 45° and within the transitional surfaces.
- Available pad space and room for a downwash caution area.
- Measured local winds on site.
- Drainage during the Oct–Nov rains.
- The views of nearby residents.
This is a desk-based planning screen using open data, not a survey, design or approval.
Scorecard
| Criterion | Rating | Evidence |
|---|---|---|
| Demand and catchment | 3/5 | There are 1,429,744 residents within 10 km and 39,158 within 2 km. Night lights radiance is 78.4. The site is listed as a cargo candidate, but the data has no figures on freight volumes. |
| Airspace | 1/5 | The site is inside prohibited area VCP22 (GND–FL300), restricted area VCR23 (GND–FL245) and the Colombo joint CTR (GND–4000 ft). Prohibited areas need a specific dispensation. VCP34 is 6.51 km away and VCP30 is 7.41 km away. |
| Terrain and approach paths | 4/5 | The site slope is 2.0° and the mean slope within 500 m is 2.4°. On the 200 m model, all 16 headings show positive 8:1 clearance of 12–22 m at 100 m, so no terrain penetration was found. Buildings and structures are not included in this check. |
| Footprint and land | 2/5 | The site cell is 48% built-up, and land within 500 m is 72% built-up and 28% tree cover. The site is inside an oil refinery, according to the airspace name. Free space for a pad of roughly 900–1,450 m² plus a downwash area is not shown in the data. |
| Wind and weather | 4/5 | ERA5 mean wind is 1.6 m/s. In the SW monsoon, wind blows from 223° with steadiness 0.94, and 3.0% of days have gusts over 15 m/s. Oct–Nov averages 400 mm of rain a month, with 16.9% of days over 20 mm. The data comes from a grid point 3.4 km away. |
| Environment and protected areas | 4/5 | The site is not in a protected area. The nearest is Bellanwila - Attidiya Sanctuary, 8.38 km away. Surface water occurrence is 0%. |
| Noise and neighbours | 3/5 | There are 1,241 residents within 500 m. OpenStreetMap shows no schools or places of worship within 500 m and no heritage features within 1 km, but OSM may be incomplete. |
| Connectivity and emergency value | 2/5 | Port City is 12.8 km away and Colombo North Teaching Hospital, Ragama, is 8.2 km away. No hospitals are mapped within 3 km. The prohibited-area status limits the site's value as a public or emergency node. |
Key risks
- The site is inside prohibited area VCP22 (GND–FL300), so no operation is possible without a specific dispensation.
- The site is also inside restricted area VCR23 and the Colombo joint CTR, so SLAF approval and air traffic control coordination would be needed.
- eVTOL batteries and charging (NFPA 855) would sit next to petroleum processing. Fire and explosion separation is unknown.
- Refinery structures are not in the 200 m terrain-only 8:1 check and could penetrate the approach surfaces.
- Downwash could reach beyond the safety area, and the people and equipment within that zone are unknown.
- There are 1,241 residents within 500 m, so noise and overflight acceptance is untested.
Open questions
- Would CAASL and the Air Force consider any dispensation for flights inside VCP22, and on what terms?
- Does the refinery operator have a cargo need that justifies on-site aircraft operations?
- What hazardous-area zoning applies on site, and where could a pad and charging equipment sit safely?
- How tall are the structures, stacks and towers along headings 225° and 45° and within the transitional surfaces?
- Is there level, debris-free ground of at least about 900–1,450 m², plus room for a downwash caution area?
- What are the measured local winds on site, including any sea breeze not captured by ERA5?
- What drainage and flood exposure is there during Oct–Nov, when rainfall averages 400 mm a month?
- Who lives and works within 500 m, and how would they be affected by noise and downwash?
Desk-based planning screen using open data (routes.evtol.lk planner layers, OpenStreetMap, ERA5 2015–2024) and the FAA Engineering Brief 105A as a design reference. It is not a survey, design or approval; Sri Lanka has not published a vertiport standard. Drafted with an AI model constrained to the data, then independently fact-checked.