At a glance
- Screening grade
- D
- District
- Nuwara Eliya
- Planner score
- 43/100
- Airspace
- none
- Residents within 2 km
- 5,139
- Departure headings
- 270° / 90°
- Coordinates
- 6.8600, 80.5840
Summary
The candidate point is on the water of Castlereagh Reservoir near Hatton, at about 1,090 m elevation. The data records the site cell as water, with 98% water occurrence and land cover 'Water'. That is the headline constraint. The FAA design reference, EB 105A, covers land-based aircraft only and excludes float and amphibian types. A pad here would need a floating or piled platform, and no published reference covers one.
Two other factors are favourable. The airspace is unconstrained on the data. Terrain leaves an east–west pair of paths with no penetration found on the 200 m model. Demand is modest. In our judgement the site grades D as given. A land site on the shore could be screened separately.
Location and catchment
The site is in Nuwara Eliya District, Central Province. Resident numbers are 22 within 500 m, 5,139 within 2 km and 164,999 within 10 km. These are night-time residents, not visitors or workers. Night-light radiance is low, at 0.4.
Base Hospital Dickoya (Hatton) is 1.9 km away. OSM lists four hospitals within 3 km, including Wanaraja Hospital at 2.5 km. The Hatton tea-country tourism point is 3.9 km away. Port City Colombo is 82.1 km away, well beyond the EH216-S's practical range of about 24 km.
The source data notes a daily Cinnamon Air service at this point, code NUF, at 1,091 m. The nature of that operation is not in our data and should be confirmed.
Airspace
The site has no airspace class and is not inside any prohibited or restricted area in the data. The nearest restricted areas are: - VCR20, Diyatalawa Army camp, at 38.0 km - VCR19, Kandy, at 46.67 km
The nearest listed airport is the SLAF Diyatalawa helipad, 41.4 km away. CAASL approval would still be needed, as Sri Lanka has no published vertiport standard.
Approach paths and terrain
Headings below are the directions the aircraft flies when departing. Each approach is the reciprocal.
The 8:1 terrain check samples the 200 m elevation model along 16 headings out to 1,219 m. Terrain alone penetrates the surface on five headings: - 000°: -5 m - 022.5°: -45 m - 045°: -10 m - 202.5°: -75 m - 225°: -92 m
Heading 247.5° is marginal, at +2 m. All headings from 067.5° to 180° and from 270° to 337.5° show +12 m.
We propose a primary departure heading of 270°. This heads into the SW-monsoon wind, which blows from 275°. The secondary departure is the reciprocal, 090°. It also roughly faces the NE-monsoon wind from 103°. No terrain penetration was found on either heading on the 200 m model. This check ignores trees, buildings, power lines and small landforms such as the reservoir banks.
Space and layout
The 500 m surroundings are 78% water and 22% tree cover, with no built area. The mean slope within 500 m is 3.0°, but the maximum is 26.5°.
For the largest Reference Aircraft (D = 15.2 m), the EB 105A Safety Area is about 38 m × 38 m, or roughly 1,450 m². That is before taxiways, charging and passenger areas. A ministry figure puts a 2-seat EH216-S-class pad at under 900 m².
Neither area exists on the candidate point, because it is water. Whether flat land of that size exists on the shore is unknown.
Wind and weather
ERA5 data for 2015–2024 come from the analysed point 1.9 km away. The model grid is about 25–30 km, so it smooths valley effects.
Winds are light: 0.8 m/s mean overall, and 1.3 m/s mean in the SW monsoon. The SW monsoon is the steadiest season, with wind from 275° and a steadiness of 0.86. WNW is the commonest direction, on 40% of days. Gusts exceed 15 m/s on 7.4% of SW-monsoon days and 20 m/s on 0.1%.
Other seasons are light and variable. The NE monsoon blows from 103° with a steadiness of 0.3.
Rain is the larger concern for VFR operations:
| Season | Rain per month | Days over 20 mm |
|---|---|---|
| Oct–Nov | 335 mm | 35.1% |
| SW monsoon | 290 mm | 9.6% |
| Mar–Apr | 210 mm | 20.5% |
| NE monsoon | 145 mm | 18.8% |
Cloud and visibility are not in the data.
Environment and neighbours
The site is not inside a protected area. Sri Pada Conservation Forest is 4.52 km away. The Central Highlands World Heritage Site is 5.45 km away.
OSM shows no schools or places of worship within 500 m and no heritage features within 1 km. OSM coverage is incomplete, so this needs checking on the ground.
Downwash over a reservoir would raise spray and water-quality questions that the data does not address. The nearest listed obstacle, Ambewela wind farm, is 22.8 km away.
What would need to be checked
- Whether a flat shoreline land site exists, who controls it, and whether it can hold a Safety Area of about 1,450 m².
- The rules of the reservoir operator and water authorities on surface use, downwash and spray.
- A data inconsistency: the 'on_land' flag reads true, but water occurrence is 98%.
- The nature of the recorded Cinnamon Air operation, and how eVTOL operations would be separated from it.
- An obstacle survey of trees, lines and structures under the 270° and 090° surfaces.
- Local cloud, visibility, wind and turbulence, using at least ten years of data as EB 105A advises.
- CAASL's position on operations at a site with no published vertiport standard.
This is a desk-based planning screen using open data, not an approval, survey or design.
Scorecard
| Criterion | Rating | Evidence |
|---|---|---|
| Demand and catchment | 2/5 | Only 22 residents live within 500 m, 5,139 within 2 km and 164,999 within 10 km. Night-light radiance is low at 0.4. The Hatton tea-country tourism point is 3.9 km away. |
| Airspace | 5/5 | The site has no airspace class and is not inside any listed area. The nearest restricted areas are VCR20 (Diyatalawa Army camp) at 38.0 km and VCR19 (Kandy) at 46.67 km. |
| Terrain and approach paths | 3/5 | Terrain penetrates the 8:1 surface on 5 of 16 headings: 000° (-5 m), 022.5° (-45 m), 045° (-10 m), 202.5° (-75 m) and 225° (-92 m). Heading 247.5° is marginal at +2 m. Headings 067.5°–180° and 270°–337.5° show +12 m on the 200 m model. |
| Footprint and land | 1/5 | The site cell is water. Water occurrence is 98% and land cover is 'Water'. The 500 m mix is 78% water and 22% tree cover, and maximum slope within 500 m is 26.5°. FAA EB 105A covers land-based aircraft only. |
| Wind and weather | 3/5 | ERA5 winds are light: 0.8 m/s mean and 3.5 m/s mean daily maximum in the SW monsoon. Gusts exceed 15 m/s on 7.4% of SW-monsoon days. Rain is heavy, at 335 mm a month in Oct–Nov, with 35.1% of those days over 20 mm. |
| Environment and protected areas | 3/5 | The site is not in a protected area. Sri Pada Conservation Forest is 4.52 km away and the Central Highlands World Heritage Site is 5.45 km away. Operating over a reservoir raises water and shoreline questions not covered by the data. |
| Noise and neighbours | 4/5 | Only 22 residents live within 500 m. OSM lists no schools or places of worship within 500 m and no heritage features within 1 km, although OSM completeness varies. |
| Connectivity and emergency value | 2/5 | Base Hospital Dickoya is 1.9 km away. Port City is 82.1 km away, well beyond the EH216-S's practical range of about 24 km. The nearest listed airport is the SLAF Diyatalawa helipad at 41.4 km. |
Key risks
- The candidate point is on water (98% occurrence). EB 105A excludes float and amphibian aircraft, so a pad would need a floating or piled platform that no published reference covers.
- Terrain penetrates the 8:1 surface to the north-north-east and south-west, by up to 92 m on heading 225°. This limits paths to an east–west and south-east sector.
- Slopes reach 26.5° within 500 m, which may make it hard to find a shoreline land pad with a flat Safety Area of about 1,450 m².
- Rainfall is heavy for VFR operations: 35.1% of Oct–Nov days and 20.5% of Mar–Apr days have more than 20 mm.
- Demand is weak. Few residents live nearby, and Port City at 82.1 km is beyond the range of the type now being tested.
- The nearby Sri Pada Conservation Forest (4.52 km) and the World Heritage Site (5.45 km) may bring route and environmental conditions.
Open questions
- Is there a suitable flat land site on the reservoir shore, and who controls it?
- What do reservoir operators and water authorities allow on the water surface, and what limits apply to downwash and spray?
- The data marks the site 'on_land: true' but 98% water occurrence. Which is correct for the actual pad position?
- What is the existing waterdrome use recorded in the data ('Cinnamon Air daily'), and how would eVTOL operations be separated from it?
- Do trees, power lines or structures on the banks penetrate the 270° and 090° approach and departure surfaces?
- How often do cloud base and visibility at 1,090 m allow VFR operations? This is not in the data.
- What local wind and turbulence do the valley terrain and banks produce? ERA5 smooths these, and an on-site record of at least ten years is advised.
- What CAASL position applies to an eVTOL operation at a site with no published vertiport standard?
Desk-based planning screen using open data (routes.evtol.lk planner layers, OpenStreetMap, ERA5 2015–2024) and the FAA Engineering Brief 105A as a design reference. It is not a survey, design or approval; Sri Lanka has not published a vertiport standard. Drafted with an AI model constrained to the data, then independently fact-checked.