At a glance

Screening grade
C
District
Kandy
Planner score
68/100
Airspace
none
Residents within 2 km
47,224
Departure headings
68° / 203°
Coordinates
7.3251, 80.6422

Summary

The data places this candidate site on the Polgolla Reservoir surface. The site cell is classed as water, with 95% water occurrence, and the site category is waterdrome. The main design reference, FAA Engineering Brief 105A, covers land-based vertiports only, so a pad on the water has no published design basis. That is the headline constraint. There is also a conflict in the data: the site is flagged as on land. Where the pad would actually go is therefore unresolved.

The demand case is strong. The site is not inside any listed restricted or prohibited area or protected area. But terrain breaks the 8:1 approach surface to the west, which is the direction the main monsoon wind comes from, and a sanctuary is 0.48 km away. On current information we grade the site C. This is a desk-based planning screen using open data, not an approval or design.

Location and catchment

The site is in Kandy District, Central Province, at about 440 m elevation. A source record notes the location as a Cinnamon Air Kandy alternate at 449 m (code KDZ).

Resident population is large:

  • 2,778 within 500 m
  • 47,224 within 2 km
  • 605,887 within 10 km

These are night-time residents, not visitors. The Temple of the Tooth is 3.5 km away. National Hospital Kandy is 4.4 km away and Kandy Private Hospital 1,797 m away. The proposed Kandy airport at Digana is 10.5 km away. Port City Colombo is 97.9 km away, far beyond the roughly 24 km practical range of the EH216-S now on test. Our judgement: local tourism and short medical links fit the data better than intercity service with current aircraft.

Airspace

The site is not inside any listed airspace, and the grid class is "none". The nearest restricted area is VCR19 (Kandy, Sri Dalada Maligawa), 1.65 km away. That is beyond the 1,219 m length of an 8:1 approach surface. However, the bearing to VCR19 is not in the data, so paths would need to be laid out to keep well clear. CAASL would regulate any operation. SLAF approval would be needed if any path entered a restricted area.

Approach paths and terrain

Headings below are the directions the aircraft flies when departing; each approach is flown on the reciprocal heading. The terrain check samples a 200 m terrain model on 16 headings.

What the data shows:

  • Blocked: terrain penetrates the 8:1 surface by 8 m at 100 m on every heading from 225° to 315°.
  • Open: all other headings have positive clearance, but only 5–12 m.

The check ignores trees, buildings and power lines. Tree cover is 67% within 500 m.

In the south-west monsoon the wind comes from 251°, so an into-wind departure would fly about 248°. That heading is blocked. We propose:

  • Primary departure: 068°. This is into the north-east monsoon wind (from 068°) and close to the March–April wind (from 049°). In the south-west monsoon the same surface supports into-wind arrivals on about 248°.
  • Secondary departure: 203°. This is 135° from the primary. It is the open heading closest to the south-west monsoon wind, about 48° off it.

On the 200 m model, no terrain penetration was found on either heading. Neither path should be treated as obstacle-free until surveyed.

Space and layout

For the largest EB 105A Reference Aircraft, the Safety Area is about 38 m × 38 m (about 1,450 m²) before taxiways, parking and charging. A ministry figure gives under 900 m² per pad for an EH216-S class site. On land, slopes are modest: 2.5° at the site cell, a mean of 3.9° within 500 m and a maximum of 9.5°. But if the pad is on the water, these figures do not describe it.

A floating or overwater platform would need its own engineering and regulatory basis. Changes in water level would also need to be understood. A shoreline pad would need land that is not identified in the data.

Wind and weather

ERA5 data (2015–2024, coarse resolution) shows a long-term mean wind of 1.4 m/s. Conditions by season:

  • South-west monsoon (May–September): wind from WSW on 87% of days, with 0.92 steadiness. Gusts exceed 15 m/s on 40.8% of days and 20 m/s on 4.4%.
  • North-east monsoon (December–February): calmer, with gusts over 15 m/s on 0.7% of days.
  • October–November: the wettest period, with 365 mm a month and 16.4% of days over 20 mm. Wind direction is variable (steadiness 0.2).

ERA5 smooths out valley and terrain effects, so turbulence around the reservoir basin is unknown.

Environment and neighbours

The site is not inside a protected area. The Victoria Randenigala Rantambe Sanctuary is 0.48 km away and Hantana EPA is 4.11 km away. Land cover within 500 m is 67% tree cover, 19% water and 14% built-up. OSM lists one school, Colombo International School, 229 m away. It lists no places of worship within 500 m and no heritage features within 1 km, but OSM coverage is incomplete. FAA research found outwash well above the 55.5 km/h caution threshold at 38.5 m from the TLOF centre for some designs. Downwash caution areas can therefore extend beyond the Safety Area and the site boundary. People must be kept out of them during operations.

What would need to be checked

  • Whether the pad would be on the water or on the shore, and the regulatory basis for either.
  • An obstacle survey of trees, buildings and lines under the 068° and 203° surfaces.
  • Where VCR19 lies relative to the proposed paths.
  • Wildlife consultation on the nearby sanctuary.
  • Noise and downwash effects on the school and nearby homes.
  • On-site wind measurement, ideally against ten years of records.

This is a desk-based planning screen using open data, not an approval, survey or design.

Scorecard

CriterionRatingEvidence
Demand and catchment4/5605,887 residents within 10 km and 47,224 within 2 km. The Temple of the Tooth is 3.5 km away. Figures are night-time residents, not visitors.
Airspace3/5Not inside any listed prohibited or restricted area, and the grid airspace class is 'none'. Restricted area VCR19 (Kandy, Sri Dalada Maligawa) is 1.65 km away, which is beyond the 1,219 m approach surface length but close enough to need checking.
Terrain and approach paths2/5On the 200 m model, terrain penetrates the 8:1 surface by 8 m at 100 m on all headings from 225° to 315°. Other headings clear by only 5–12 m, and that check ignores trees, which cover 67% of the area within 500 m.
Footprint and land1/5The site cell is classed as water, with 95% water occurrence, and the category is waterdrome. EB 105A covers land-based vertiports only. The data's on_land flag is 'true', which conflicts with this, so the actual pad location is unresolved.
Wind and weather3/5In the SW monsoon the wind comes from 251° (WSW) with 0.92 steadiness. Gusts exceed 15 m/s on 40.8% of days and 20 m/s on 4.4%. October–November averages 365 mm of rain a month, with 16.4% of days over 20 mm and a wind steadiness of only 0.2.
Environment and protected areas3/5Not inside a protected area. The Victoria Randenigala Rantambe Sanctuary is 0.48 km away and Hantana EPA is 4.11 km away. Water makes up 19% and tree cover 67% of land cover within 500 m.
Noise and neighbours2/52,778 residents live within 500 m. OSM lists one school (Colombo International School) 229 m away. Built-up land covers 14% within 500 m and 9% of the site cell.
Connectivity and emergency value3/5National Hospital Kandy is 4.4 km away and Kandy Private Hospital 1,797 m away. The proposed Kandy airport (Digana) is 10.5 km away. Port City is 97.9 km away, well beyond the EH216-S's practical range of about 24 km.

Key risks

  • The site is on a reservoir surface (95% water occurrence), outside EB 105A's land-based scope. A water or floating pad has no published design basis.
  • Terrain penetrates the 8:1 surface on headings from 225° to 315°. This rules out into-wind departures in the SW monsoon, when gusts exceed 15 m/s on 40.8% of days.
  • Margins on the open headings are thin (5–12 m on the 200 m model). Tree cover of 67% within 500 m is not counted in the terrain check.
  • A sanctuary (Victoria Randenigala Rantambe) is 0.48 km away, and the area within 500 m is 19% water.
  • There are 2,778 residents and one school (229 m) within 500 m. The downwash and noise exposure is sensitive.
  • Restricted area VCR19 lies 1.65 km away. Approach and departure paths should keep clear of it, or SLAF approval would be needed.

Open questions

  • Is the pad meant to be on the water (floating) or on the shore? What explains the conflict between the on_land flag and 95% water occurrence?
  • What regulatory basis would CAASL apply to a water-based or floating vertiport for an eVTOL?
  • How far do reservoir water levels vary, and can a fixed or floating platform meet the TLOF/FATO and Safety Area requirements?
  • What is the bearing from the site to restricted area VCR19, and do any proposed paths come near it?
  • How high are the trees, buildings and power lines under the 068° and 203° surfaces? A full obstacle survey is needed.
  • Would wildlife or other authorities need to assess flights 0.48 km from the Victoria Randenigala Rantambe Sanctuary?
  • What are the noise and downwash impacts on the school 229 m away and on nearby homes?
  • What does on-site wind measurement show about local valley and terrain effects that ERA5 smooths out, especially gusts in the SW monsoon?

Desk-based planning screen using open data (routes.evtol.lk planner layers, OpenStreetMap, ERA5 2015–2024) and the FAA Engineering Brief 105A as a design reference. It is not a survey, design or approval; Sri Lanka has not published a vertiport standard. Drafted with an AI model constrained to the data, then independently fact-checked.