At a glance
- Screening grade
- C
- District
- Puttalam
- Planner score
- 26/100
- Airspace
- Danger area (NOTAM)
- Residents within 2 km
- 4,037
- Departure headings
- 225° / 45°
- Coordinates
- 8.0184, 79.7225
Summary
This candidate sits at the Lakvijaya coal plant, Norochcholai, in Puttalam District, North Western Province. The headline constraint is airspace. The site lies inside two gun-firing danger areas: VCD6 (Kalpitiya/Puttalam lagoon, surface to 10,000 ft) and VCD35 (Kalpitiya peninsula, surface to FL250). The second constraint is obstacles. The data lists the power station stacks as the nearest obstacle at 0.0 km, so the mapped point is effectively at the stacks. The ground is flat and low. Demand is weak apart from the plant's own possible cargo needs. Our judgement is grade C: significant constraints and a weak demand case. Cargo is the only use worth testing.
This is a desk-based planning screen using open data. It is not an approval, a survey or a design.
Location and catchment
The site is at 0 m elevation. Residents number 2,011 within 500 m, 4,037 within 2 km and 39,448 within 10 km. These are night-time resident counts, not workers or visitors. Night-light radiance is 9.5.
Distances to key places: - Port City Colombo: 120.7 km. The EH216-S on test has a practical range of about 24 km, so a link to Colombo would need a much longer-range aircraft. - Base Hospital Puttalam: 12.9 km. - Unnamed hospital in OpenStreetMap: 2,891 m. - Kalpitiya, the nearest tourism point: 24.8 km. - SLAF Palavi: 15.4 km.
In our judgement, passenger, tourism and medical cases are weak. Any case rests on logistics for the plant.
Airspace
The data shows the site inside VCD6 and VCD35. Both are gun-firing danger areas that start at the surface. They are normally activated by NOTAM. Danger areas are not prohibited or restricted areas in the data. Even so, operating inside active firing areas is not compatible with routine flights. Any scheme would need SLAF and CAASL to agree how activations are scheduled and deconflicted.
Training area VCT-G is 12.36 km away, and restricted area VCR11 (SLAF Base Anuradhapura) is 75.03 km away. Sri Lanka has no published vertiport standard, and CAASL would regulate any operation.
Approach paths and terrain
Convention: a heading is the direction the aircraft flies on departure; the approach is flown along the reciprocal.
- Primary heading: 225°. This faces into the SW monsoon wind, which blows from 219° with a steadiness of 0.97.
- Secondary heading: 45°. This is reciprocal to the primary and faces into the NE monsoon wind, which blows from 47°.
The 8:1 terrain check found 12 m minimum clearance at 100 m on all 16 headings. That means no terrain penetration was found on the 200 m model. The check ignores structures. Stacks are listed at the site itself, and the data notes wind farms nearby. Stack heights, wind turbine positions and plume effects must be surveyed before any path can be fixed. Under FAA EB 105A the 8:1 surface reaches about 152 m above the pad at 1,219 m. Tall stacks near the pad could penetrate it on several headings.
Space and layout
The site has a slope of 0.5°, with a mean of 0.2° and a maximum of 1.0° within 500 m. Land cover at the site is built-up (40% built). Within 500 m the mix is 33% built-up, 31% water and 19% cropland.
For the largest FAA Reference Aircraft, the Safety Area alone is about 38 m × 38 m (about 1,450 m²). A ministry figure gives under 900 m² per pad for a 2-seat EH216-S class vertiport. The flat terrain suits a ground-level pad. Whether land is free inside an operating power plant is unknown.
Wind and weather
The ERA5 figures (2015–2024) are taken from a point 12.9 km away, and the model is coarse.
| Season | Wind | Gusts and rain |
|---|---|---|
| SW monsoon (May–Sep) | From 219°, mean 5.2 m/s, mean daily maximum 5.9 m/s | 18.0% of days have gusts over 15 m/s; 45 mm/month |
| NE monsoon (Dec–Feb) | From 47°, mean 3.3 m/s | 75 mm/month |
| Mar–Apr | Direction unsettled (steadiness 0.25) | 115 mm/month |
| Oct–Nov | Direction unsettled (steadiness 0.14) | 260 mm/month; 12.3% of days over 20 mm |
In our judgement, the SW monsoon gusts and the Oct–Nov rain would limit flying days. Flow around the stacks and plant buildings may add turbulence, and ERA5 cannot show this.
Environment and neighbours
The site is not in a protected area and no nearby protected areas are listed. It is on land, with 0% water occurrence. OpenStreetMap shows no schools or places of worship within 500 m and no heritage features within 1 km. OSM completeness varies.
About 2,011 residents live within 500 m. Downwash and outwash may extend beyond the Safety Area. FAA research found high velocities at 38.5 m from the pad centre for some designs, so a Downwash Caution Area plan is needed.
What would need to be checked
- How often VCD6 and VCD35 are active, and whether SLAF and CAASL would permit operations inside them.
- Stack heights and positions, and plume turbulence and heat at pad height.
- Wind farm locations and turbine heights.
- Whether the plant operator has a cargo need and land available for a pad.
- Where the nearby water lies, and whether paths can be routed over it.
- On-site wind measurement, including sea-breeze effects.
- Fire and energy-storage safety (NFPA 418/855) on an industrial fuel site.
This is a desk-based planning screen using open data, not an approval.
Scorecard
| Criterion | Rating | Evidence |
|---|---|---|
| Demand and catchment | 2/5 | 2,011 residents within 500 m, 4,037 within 2 km and 39,448 within 10 km (night-time residents). Night-light radiance is 9.5. Any demand would likely come from the plant itself, which the data does not quantify. |
| Airspace | 1/5 | The site is inside danger area VCD6 (gun firing, Kalpitiya/Puttalam lagoon, SFC–10,000 ft) and VCD35 (gun firing, Kalpitiya peninsula, SFC–FL250). Training area VCT-G is 12.36 km away and SLAF Palavi is 15.4 km away. |
| Terrain and approach paths | 2/5 | No terrain penetration was found on the 200 m model on any of 16 headings (minimum clearance 12 m at 100 m on every heading). However, the nearest obstacle listed is the power station stacks at 0.0 km, and wind farms are noted nearby. Neither is captured by the terrain check. |
| Footprint and land | 3/5 | Elevation 0 m, site slope 0.5° and maximum slope 1.0° within 500 m. Land cover at the site is built-up (40% built). Within 500 m the mix is 33% built-up, 31% water and 19% cropland. Whether a pad can fit within the plant boundary is not known. |
| Wind and weather | 3/5 | The SW monsoon is steady from 219° (steadiness 0.97), but 18.0% of days have gusts over 15 m/s. Oct–Nov averages 260 mm/month, with 12.3% of days over 20 mm. The ERA5 figures come from a point 12.9 km away. |
| Environment and protected areas | 4/5 | The site is not in a protected area and no nearby protected areas are listed. It is on land (water occurrence 0%), although water covers 31% of the area within 500 m. |
| Noise and neighbours | 3/5 | OSM shows no schools or places of worship within 500 m and no heritage features within 1 km, though OSM coverage is incomplete. There are still 2,011 residents within 500 m. |
| Connectivity and emergency value | 2/5 | Base Hospital Puttalam is 12.9 km away and an unnamed OSM hospital is 2,891 m away. Port City is 120.7 km away, far beyond the 24 km practical range of the EH216-S on test. Kalpitiya is 24.8 km away. |
Key risks
- The site is inside gun-firing danger areas VCD6 (SFC–10,000 ft) and VCD35 (SFC–FL250), which are activated by NOTAM.
- The power station stacks are listed as the nearest obstacle at 0.0 km. Their heights and positions relative to any pad are unknown.
- Wind farms are noted nearby but are not in the terrain model.
- Gusts over 15 m/s occur on 18.0% of SW monsoon days.
- Heavy Oct–Nov rain (260 mm/month; 12.3% of days over 20 mm).
- Weak passenger and medical demand: Port City is 120.7 km away and Base Hospital Puttalam is 12.9 km away.
Open questions
- How often VCD6 and VCD35 are active, and whether SLAF and CAASL would permit eVTOL operations inside them.
- Heights and exact positions of the power station stacks and other plant structures.
- Location and tip heights of the nearby wind farms.
- Whether the plant operator has a cargo need and land inside the boundary for a pad (Safety Area about 38 m × 38 m for the largest Reference Aircraft).
- Turbulence and heat from stack plumes and plant buildings at pad height.
- Which side of the site the water lies on, and whether approach paths can be routed over it.
- On-site wind measurements to confirm local sea-breeze effects, which ERA5 does not resolve.
- Fire protection and energy-storage arrangements (NFPA 418/855) next to an industrial fuel site.
Desk-based planning screen using open data (routes.evtol.lk planner layers, OpenStreetMap, ERA5 2015–2024) and the FAA Engineering Brief 105A as a design reference. It is not a survey, design or approval; Sri Lanka has not published a vertiport standard. Drafted with an AI model constrained to the data, then independently fact-checked.